Storage
The most common storage mistake is comparing price per terabyte first. Until usable capacity, performance target and recovery objective are fixed, price comparison has no meaning.
Start with three numbers
Capacity means usable capacity, not raw. RAID level and hot spares take a share first, then snapshots and replicas. Add three years of growth on top; that total is what should be purchased now. Buying to current capacity and expanding a year later is usually more expensive once expansion enclosures, downtime windows and data redistribution are counted.
Performance depends on the actual IO model — block, file or object; read/write ratio; random or sequential; latency-sensitive or throughput-sensitive. Comparing peak IOPS alone turns a shared-file workload into an all-flash configuration.
Recovery objectives set the design. RPO determines backup frequency and replication method; RTO determines whether recovery runs from local snapshots, from backup media, or by failing over to a second site. Without these two numbers, the gap between "we have backups" and "we can recover" stays open.
Six directions, six trade-offs
These are design trade-offs rather than product categories. Whether the budget goes to capacity or performance depends on the three numbers above.
All-flash arrays
Latency-sensitive workloads such as databases and virtualisation; look at stable latency, not peak IOPS.
Hybrid arrays
A capacity/performance compromise for file sharing and general workloads; tiering policy drives the real experience.
Distributed storage
Scale-out, object and big-data workloads; expansion by node, with network and operational complexity to assess.
Backup and recovery
Designed against RPO/RTO; the metric that matters is recoverability, not job success rate.
DR and active-active
Same-city or remote, driven by acceptable failover time, data loss and link budget.
Archive and cold data
Retention period and retrieval frequency first, media second.
Delivery scope
| Item | Included |
|---|---|
| Capacity and performance assessment | Current utilisation, IO model and growth trend; usable capacity calculation |
| Options and comparison | At least two architectures (centralised or distributed) with price difference explained |
| Compatibility check | Multipathing, HBAs, switches, OS and virtualisation versions |
| Racking and initialisation | Installation, pool and RAID configuration, multipathing and link aggregation |
| Data migration | Migration plan, verification method and rollback; a separate line item |
| Monitoring and acceptance | Capacity and performance alerts, acceptance tests, documentation |
Data migration and cutover are not part of standard delivery and are quoted separately against downtime window and data volume.
Four steps to a design
Collect
Existing capacity, IO model, growth curve and twelve months of incidents.
Design
Architecture from usable capacity, performance and recovery targets — brand decided last.
Verify
Test the IO path and the recovery path, including one real restore.
Deliver
Racking, migration, monitoring and acceptance; the migration window is scheduled separately.
Storage questions we hear most
Is all-flash always better than hybrid?
For latency-sensitive, random-read workloads at controlled data volumes, usually yes. For large file-sharing estates where access concentrates on a small hot set, hybrid with tiering is often better value. The deciding factor is the IO model, not the medium.
Can distributed storage replace a centralised array?
For scale-out, object or big-data workloads, yes, and expansion is smoother. The cost is heavier network dependency and operational complexity; at small scale the unit cost is not necessarily lower.
Does a 100% backup success rate mean we are safe?
No. Success rate only means jobs completed, not that data can be restored. Our acceptance includes at least one full restore drill with the actual elapsed time recorded — that time is the real RTO.
Need a capacity and architecture review?
Send existing models, utilisation levels and three-year growth expectations; we will return a usable-capacity calculation and two architecture options.